AURUMED Uni-Plus

Type 3
white / Au 2.0 
copper-free

Composition: Au 2.0 /Ag 58.0 / Pd 32.9 / Zn 3.5 / Sn 2.0 /
In 1,5 / Ir 0.05 / Ru 0.05
Standard: DIN EN ISO 22674 und DIN EN ISO 9693
Colour: white
Melting range °C: 1125-1040
Soft annealing: 15 mins at 800 ° C / quench in water
Hardening: 15 mins at 550 °C / air
Preheating temperature °C: 800
Casting temperature °C: 1275
Further heating after melting (secs): electr.: 20–30
inductive: 5–10
flame: 5–10
Density g/cm3: 11,0
CTE 25°C–500°C (µm/mK): 16,2
CTE 25°C–600°C (µm/mK): 16,4
Soldering before firing: Orplid Ceramic solder CF 950
Soldering after firing: Orplid solder CF 720
Vickers hardness (HV 5/30): w: 145
a: 195
g/b: 165/150
0.2% proof stress (MPa): w: 276
a: 324
g/b: 288/275
Elongation at break (%): w: 15
a: 9
g/b: 8/12
Spruing: Following the rules for dental applications (see General Instructions for Use)
Investment: Phosphate-bonded investment materials 
Preheating: 800 °C, 30 to 90 mins until end temperature, depending on size of mould
Casting: 1275°C – possibly increase by 20°C–30°C for resistance-heated casting units. Use ceramic crucible (graphite crucibles also possible)
Finishing: With carbide burs and/or ceramic-bonded stones. Always grind in one direction only! Sandblasting at a flat angle, using 110–150 µm aluminium oxide. Pressure should not exceed 2 bar
Cleaning: Steam jet cleaning or boiling in distilled water
Oxide firing: 10 mins at 800°C without vacuum. Afterwards, always clean in a preheated acid bath, e.g. Neacid, (for 10 mins) or sandblast with 50–110 µm aluminium oxide. Pressure should not exceed 2 bar. Clean thoroughly with a steam jet
Soldering before firing: Orplid Ceramic solder CF 950
Soldering after firing: Orplid solder CF 720
Firing: For highly expanding ceramic materials